Phone: (248) 496-7375 | Fax: (803) 329-5237 | Email: ctassociates@msn.com

superflash
SuperFlash - Compressed Gas Equipment

Manifold & Pipeline Flashback Arrestors

 
SIMAX Series
Ideal for high volume gas flow applications, the SIMAX series of flashback arrestors provides a full range of dry type flashback, gas reverse flow, and hose burn back protection in a compact, economical unit. With no water or fluid to check or refill, many professionals find these units to be highly convenient. SIMEX flash back arrestors are approved under ANSI Z49.1 2012 safety guidelines, and help meet OSHA, NFPA, and other industry safety standards.

Type of Gas Model Inlet Outlet Part No.
Fuel Gas SIMAX 3 1" NPT F 1" NPT F 0701-3270
  SIMAX 5 1" NPT F 1" NPT F 0701-3271
  SIMAX 8 1" NPT F 1" NPT F 0701-3279
Type of Gas Model Inlet Outlet Part No.
Oxygen SIMAX 3 1" NPT F 1" NPT F 0701-3191
  SIMAX 5 1" NPT F 1" NPT F 0701-3192
  SIMAX 8 1" NPT F 1" NPT F 0701-3197
dry type flame arrestor
 
 
DEMAX Series
Designed to help high gas volume pipelines and tapping points meet ANSI Z49.1 2012, OSHA, and NFPA safety guidelines. The DEMAX series is great for manifold systems and pipelines. It includes an inlet filter, reverse flow check valve, flame barrier, and thermal cut off in one compact brass body. One (1") NPT female inlet and outlet makes installation easy. Also available in Stainless Steel .

Type of Gas Inlet Outlet Part No.
Fuel Gas (LH) 7/8" UNF3 F 7/8" UNF3 M 0701-3302
Fuel Gas 1" NPT F 1" NPT F 0701-3304
Oxygen (RH) 7/8" UNF3 F 7/8" UNF3 M 0701-3300
Oxygen 1" NPT F 1" NPT F 0701-3307
pipeline flash arrestor
3   CGA Class "C" Connection
 
 
DEMAX SIMAX 3 SIMAX 5 SIMAX 8
For Fuel Gas
Up to 2,600 ft3/hr
airflow at 50 PSIG.
For Fuel Gas
Up to 3,600 ft3/hr
airflow at 50 PSIG.
For Fuel Gas
Up to 5,900 ft3/hr
airflow at 50 PSIG.
For Fuel Gas
Up to 9,500 ft3/hr
airflow at 50 PSIG.
For Oxygen
Up to 7,600 ft3/hr
airflow at 143 PSIG.
For Oxygen
Up to 9,215 ft3/hr
airflow at 143 PSIG.
For Oxygen
Up to 14,250 ft3/hr
airflow at 143 PSIG.
For Oxygen
Up to 23,750 ft3/hr
airflow at 143 PSIG.
 
 
For details, please call us at (248) 496-7375, or email us at ctassociates@msn.com.
 
 