UL and BAM approved, and 100% tested for reverse flow, leak integrity and flashback protection with actual flashbacks, SuperFlash's flashback arrestors are the worldwide leader in safety, quality, and functionality. Each arrestor contains a built-in 100 micron inlet filter, reverse flow check valve, 3-5 micron flame barrier, and a thermal shutoff valve in point of supply models. Not only will you receive adequate gas flow, you will have the highest quality safety device available.
 
Standard Flow: Regulator
To help meet ANSI Z49.1 2012, OHSA, and NFPA safety requirements while protecting against the most common accidents we offer the DGN model, which installs easily on the outlet fitting of most regulators and gas supply points. Each flashback arrestor is 100% tested with actual flashbacks, and have built in 100 micron inlet filters, reverse flow check valves, flame barriers, and thermal shut off valves. Model DGND includes all the features of the DGN with the addition of a pressure relief valve that vents excess pressure to the atmosphere.

Type of Gas Inlet Outlet Part No.
Fuel Gas (LH) 9/16" UNF1 F 9/16" UNF1 M 0701-4123
  1/4" NPT F 1/4" NPT F EDI-0004
  1/4" NPT F 1/4" NPT F 0701-0299
Hydrogen (LH) RR 41/64"2 F RR 41/64"2 M 0701-4350*
Oxygen (RH) 9/16" UNF1 F 9/16" UNF1 M 0701-4128
  1/4" NPT F 1/4" NPT F EDI-0001
  RR 41/64"2 F RR 41/64"2 M 0701-0312
 
 
Standard Flow: Torch
Torch and Point-of-Use flashback arrestors are a combination of flame barrier and reverse flow check valve in one unit. They help to protect the operator at the torch, or point-of-use, from flashback and reverse flow of gases.

Type of Gas Inlet Outlet Part No.
Fuel Gas (LH) 9/16" UNF1 M 9/16" UNF1 F 0701-2064
  RR 41/64"2 F RR 41/64"2 M 0701-3045
Oxygen (RH) 9/16" UNF1 M 9/16" UNF1 F 0701-2070
  RR 41/64"2 F RR 41/64"2 F 0701-3044
1   CGA Class "B" Connection
2   CGA Connection used by Railroads
 
 

  Model GG Airflow

Inlet Pressure
PSIG**
Airflow
FT3 / H
7.3 100.0
14.5 197.0
21.8 309.0
36.3 521.0
72.7 929.0

  **PSIG = pounds per square inch gauge

 
For details, please call us at (248) 496-7375, or email us at ctassociates@msn.com.
 
 
Return to SuperFlash main page
 

 



This Page Copyright 2005 C.T. & Associates LLC. all trademarks, copyrights, and registered logos belong to their respective owners

Main  |    Contact Us   |  Product Lines  |  Manufacturer's Web Sites

Phone: (248) 496-7375 | Fax: (803) 329-5237 | Email: ctassociates@msn.com